MRI software for diffusion-perfusion mismatch analysis may impact on patients' selection and clinical outcome.

Fiche du document

Type de document
Périmètre
Langue
Identifiants
Relations

Ce document est lié à :
info:eu-repo/semantics/altIdentifier/doi/10.1007/s00330-021-08211-2

Ce document est lié à :
info:eu-repo/semantics/altIdentifier/pmid/34350507

Ce document est lié à :
info:eu-repo/semantics/altIdentifier/eissn/1432-1084

Ce document est lié à :
info:eu-repo/semantics/altIdentifier/urn/urn:nbn:ch:serval-BIB_3EB793463DD79

Licences

info:eu-repo/semantics/openAccess , CC BY 4.0 , https://creativecommons.org/licenses/by/4.0/




Citer ce document

S. Pistocchi et al., « MRI software for diffusion-perfusion mismatch analysis may impact on patients' selection and clinical outcome. », Serveur académique Lausannois, ID : 10.1007/s00330-021-08211-2


Métriques


Partage / Export

Résumé 0

Impact of different MR perfusion software on selection and outcome of patients with acute ischemic stroke (AIS) and large vessel occlusion (LVO) treated by endovascular thrombectomy (EVT) is unclear. We aimed at comparing two commercial MRI software, semi-automated with unadjusted (method A) and adjusted mask (method B), and fully automated (method C) in this setting. MRI from 144 consecutive AIS patients with anterior circulation LVO was retrospectively analysed. All diffusion- and perfusion-weighted images (DWI-PWI) were post-processed with the three methods using standard thresholds. Concordance for core and hypoperfusion volumes was assessed with Lin's test. Clinical outcome was compared between groups in patients who underwent successful EVT in the early and late time window. Mean core volume was higher and mean hypoperfusion volume was lower in method C than in methods A and B. In the early time window, methods A and B found fewer patients with a mismatch ratio ≤ 1.2 than method C (1/67 [1.5%] vs. 12/67 [17.9%], p = 0.0013). In the late time window, methods A and B found fewer patients with a mismatch ratio < 1.8 than method C (3/46 [6.5%] and 2/46 [4.3%] vs. 18/46 [39.1%], p ≤ 0.0002). More patients with functional independence at 3 months would not have been treated using method C versus methods A and B in the early (p = 0.0063) and late (p ≤ 0.011) time window. MRI software for DWI-PWI analysis may influence patients' selection before EVT and clinical outcome. • Method C detects fewer patients with favourable mismatch profile. • Method C might underselect more patients with functional independence at 3 months. • Software used before thrombectomy may influence patients' outcome.

document thumbnail

Par les mêmes auteurs

Sur les mêmes sujets

Exporter en