Optimization of venous return tubing diameter for cardiopulmonary bypass

Fiche du document

Type de document
Périmètre
Identifiant
Relations

Ce document est lié à :
info:eu-repo/semantics/altIdentifier/doi/10.1016/S1010-7940(01)00840-5

Ce document est lié à :
info:eu-repo/semantics/altIdentifier/pmid/11509288

Ce document est lié à :
info:eu-repo/semantics/altIdentifier/pissn/1010-7940

Ce document est lié à :
info:eu-repo/semantics/altIdentifier/urn/urn:nbn:ch:serval-BIB_1752EB4F20946

Licences

info:eu-repo/semantics/openAccess , Copying allowed only for non-profit organizations , https://serval.unil.ch/disclaimer



Sujets proches En

Tubular goods Tubing

Citer ce document

Y. M. Ni et al., « Optimization of venous return tubing diameter for cardiopulmonary bypass », Serveur académique Lausannois, ID : 10.1016/S1010-7940(01


Métriques


Partage / Export

Résumé 0

OBJECTIVE: To determine the optimal venous tubing diameter for adult cardiopulmonary bypass (CPB) to improve gravity drainage and to reduce priming volume. METHODS: (A) Maximum bovine blood flow rates by gravity drainage were assessed in vitro for four different tubing diameters (1/2, 3/8, 5/16,1/4 inch) with three different lengths and various pre- and afterloads. Based on the results of (A) and multiple regression analyses, we developed equations to predict tubing sizes as a function of target flows. (C) The equations obtained in (B) were validated by ex vivo bovine experiments. (D) The clinically required maximal flows were determined retrospectively by reviewing 119 perfusion records at Zurich University. (E) Based on our model (B), the clinical patient and hardware requirements, the optimal venous tubing diameter was calculated. (F) The optimized venous tubing was evaluated in a prospective clinical trial involving 312 patients in Hangzhou. RESULTS: For a mean body surface area of 1.83+/-0.2 m(2), the maximal perfusion flow rate (D) achieved with 1/2-inch (=1.27 cm(2)) venous tubing was 4.62+/-0.57 l/min (range: 2.50-6.24 l/min). Our validated model (B,C) predicted 1.0 cm(2) as optimal cross-sectional area for the venous line. New tubing packs developed accordingly were used routinely thereafter. The maximal flow rate was 4.93+/-0.58 l/min (range: 3.9-7.0) in patients with a mean body surface area of 1.62+/-0.21 m(2). CONCLUSION: The new venous tubing with 1.0-cm(2) cross-sectional area improves the drainage in the vast majority of adult patients undergoing CPB and reduces the priming volume (-27 ml/m). Reduced hemodilution can prevent homologous transfusions if a predefined transfusion trigger level is not reached.

document thumbnail

Par les mêmes auteurs

Sur les mêmes sujets

Exporter en