Ion mobility-high resolution mass spectrometry in anti-doping analysis. Part I: Implementation of a screening method with the assessment of a library of substances prohibited in sports.

Fiche du document

Date

1 avril 2021

Type de document
Périmètre
Langue
Identifiants
Relations

Ce document est lié à :
info:eu-repo/semantics/altIdentifier/doi/10.1016/j.aca.2021.338257

Ce document est lié à :
info:eu-repo/semantics/altIdentifier/pmid/33648637

Ce document est lié à :
info:eu-repo/semantics/altIdentifier/eissn/1873-4324

Ce document est lié à :
info:eu-repo/semantics/altIdentifier/urn/urn:nbn:ch:serval-BIB_E4C07E3B5A726

Licences

info:eu-repo/semantics/openAccess , CC BY 4.0 , https://creativecommons.org/licenses/by/4.0/




Citer ce document

K. Plachká et al., « Ion mobility-high resolution mass spectrometry in anti-doping analysis. Part I: Implementation of a screening method with the assessment of a library of substances prohibited in sports. », Serveur académique Lausannois, ID : 10.1016/j.aca.2021.338257


Métriques


Partage / Export

Résumé 0

In this series of two papers, 192 doping agents belonging to the classes of stimulants, narcotics, cannabinoids, diuretics, β2-agonists, β-blockers, anabolic agents, and hormone and metabolic modulators were investigated, with the aim to assess the benefits and limitations of ion mobility spectrometry (IMS) in combination with ultra-high performance liquid chromatography (UHPLC) and high resolution mass spectrometry (HRMS) in anti-doping analysis. In this first part, a generic UHPLC-IM-HRMS method was successfully developed to analyze these 192 doping agents in standard solutions and urine samples, and an exhaustive database including retention times, TW CCS N2 values, and m/z ratios was constructed. Urine samples were analyzed using either a simple "dilute and shoot" procedure or a supported liquid-liquid extraction (SLE) procedure, depending on the physicochemical properties of the compounds and sensitivity criteria established by the World Anti-Doping Agency (WADA) as the minimum required performance levels (MRPL). Then, the precision of the generic UHPLC-IM-HRMS method was assessed as intraday, interday as well as interweek variation of UHPLC retention times and TW CCS N2 values, for which RSD the values were always lower than 2% in urine samples. The possibility to filter MS data using IMS dimension was also investigated, and in average, the application of IMS filtration provided low energy MS spectra with 86% less interfering peaks in both standard and urine samples. Therefore, the filtered MS spectra allowed for an easier interpretation and a lower risk of false positive result interpretations. Finally, IMS also offers additional selectivity to the UHPLC-HRMS enabling to separate isobaric and isomeric substances. Among the selected set of 192 doping agents, there were 30 pairs of isobaric or isomeric compounds, and only two pairs could not be resolved under the developed conditions. This illustrates the potential of adding ion mobility to UHPLC-HRMS in anti-doping analyses.