Performance evaluation of the Becton Dickinson Kiestra™ IdentifA/SusceptA.

Fiche du document

Type de document
Périmètre
Langue
Identifiants
Relations

Ce document est lié à :
info:eu-repo/semantics/altIdentifier/doi/10.1016/j.cmi.2020.09.050

Ce document est lié à :
info:eu-repo/semantics/altIdentifier/pmid/33031951

Ce document est lié à :
info:eu-repo/semantics/altIdentifier/eissn/1469-0691

Ce document est lié à :
info:eu-repo/semantics/altIdentifier/urn/urn:nbn:ch:serval-BIB_85C11972FFBD0

Licences

info:eu-repo/semantics/openAccess , CC BY-NC-ND 4.0 , https://creativecommons.org/licenses/by-nc-nd/4.0/



Sujets proches En

Competence

Citer ce document

D. Jacot et al., « Performance evaluation of the Becton Dickinson Kiestra™ IdentifA/SusceptA. », Serveur académique Lausannois, ID : 10.1016/j.cmi.2020.09.050


Métriques


Partage / Export

Résumé 0

New automated modules are required to provide fully automated solutions in diagnostic microbiology laboratories. We evaluated the performance of a Becton Dickinson Kiestra™ IdentifA/SusceptA prototype for MALDI-TOF identification (ID) and Phoenix™ antibiotic susceptibility testing (AST). The performance of the IdentifA/SusceptA coupled prototype was compared with manual processing for MALDI-TOF ID on 1302 clinical microbial isolates or ATCC strains and for Phoenix™ M50 AST on 484 strains, representing 61 species. Overall, the IdentifA exhibited similar ID performances than manual spotting. Higher performances were observed for Gram-negative bacteria with an ID at the species level (score >2) of 96.5% (369/382) and 86.9% (334/384), respectively. A significantly better performance was observed with the IdentifA (95.2%, 81/85) compared with manual spotting (75.2%, 64/85) from colonies on MacConkey agar. Contrariwise, the IdentifA exhibited lower ID performances at the species level than manual processing for streptococci (76.1%, 96/126 compared with 92%, 115/125), coagulase-negative staphylococci (73.3%, 44/60 compared with 90%, 54/60) and yeasts (41.3%, 19/46 compared with 78.2%, 36/46). Staphylococcus aureus and enterococci were similarly identified by the two approaches, with ID rates of 92% (65/70) for the IdentifA and 92.7%, (64/69) for manual processing and 94.8%, (55/58) for the IdentifA and 98.2%, (57/58) for manual processing, respectively. The SusceptA exhibited an AST overall essential agreement of 98.82% (6863/6945), a category agreement of 98.86% (6866/6945), 1.05% (6/570) very major errors, 0.16% (10/6290) major errors, and 0.91% (63/6945) minor errors compared to the reference AST. Overall, the automated IdentifA/SusceptA exhibited high ID and AST performances.