Reproducibility of measurements of potential doubling time of tumour cells in the multicentre National Cancer Institute protocol T92-0045.

Fiche du document

Date

1999

Type de document
Périmètre
Langue
Identifiant
Relations

Ce document est lié à :
info:eu-repo/semantics/altIdentifier/doi/10.1038/sj.bjc.6690052

Ce document est lié à :
info:eu-repo/semantics/altIdentifier/pmid/9888476

Ce document est lié à :
info:eu-repo/semantics/altIdentifier/pissn/0007-0920

Ce document est lié à :
info:eu-repo/semantics/altIdentifier/urn/urn:nbn:ch:serval-BIB_135948

Licences

info:eu-repo/semantics/openAccess , Copying allowed only for non-profit organizations , https://serval.unil.ch/disclaimer



Sujets proches En

Measuring Mensuration

Citer ce document

G.D. Wilson et al., « Reproducibility of measurements of potential doubling time of tumour cells in the multicentre National Cancer Institute protocol T92-0045. », Serveur académique Lausannois, ID : 10.1038/sj.bjc.6690052


Métriques


Partage / Export

Résumé 0

We compared the flow cytometric measurement and analysis of the potential doubling time (Tpot) between three centres involved in the National Cancer Institute (NCI) protocol T92-0045. The primary purpose was to understand and minimize the variation within the measurement. A total of 102 specimens were selected at random from patients entered into the trial. Samples were prepared, stained, run and analysed in each centre and a single set of data analysed by all three centres. Analysis of the disc data set revealed that the measurement of labelling index (LI) was robust and reproducible. The estimation of duration of S-phase (T(S)) was subject to errors of profile interpretation, particularly DNA ploidy status, and analysis. The LI dominated the variation in Tpot such that the level of final agreement, after removal of outliers and ploidy agreement, reached correlation coefficients of 0.9. The sample data showed poor agreement within each of the components of the measurement. There was some improvement when ploidy was in agreement, but correlation coefficients failed to exceed values of 0.5 for Tpot. The data suggest that observer-associated analysis of T(S) and tissue processing and tumour heterogeneity were the major causes of variability in the Tpot measurement. The first two aspects can be standardized and minimized, but heterogeneity will remain a problem with biopsy techniques.

document thumbnail

Par les mêmes auteurs

Sur les mêmes sujets

Exporter en