Continuous Versus Routine Standardized Electroencephalogram for Outcome Prediction in Critically Ill Adults: Analysis From a Randomized Trial.

Fiche du document

Date

1 février 2022

Discipline
Type de document
Périmètre
Langue
Identifiants
Relations

Ce document est lié à :
info:eu-repo/semantics/altIdentifier/doi/10.1097/CCM.0000000000005311

Ce document est lié à :
info:eu-repo/semantics/altIdentifier/pmid/34582427

Ce document est lié à :
info:eu-repo/semantics/altIdentifier/eissn/1530-0293

Ce document est lié à :
info:eu-repo/semantics/altIdentifier/urn/urn:nbn:ch:serval-BIB_6DFA540F10C43

Licences

info:eu-repo/semantics/openAccess , CC BY-NC-ND 4.0 , https://creativecommons.org/licenses/by-nc-nd/4.0/



Sujets proches En

Encephalography EEG

Citer ce document

I. Beuchat et al., « Continuous Versus Routine Standardized Electroencephalogram for Outcome Prediction in Critically Ill Adults: Analysis From a Randomized Trial. », Serveur académique Lausannois, ID : 10.1097/CCM.0000000000005311


Métriques


Partage / Export

Résumé 0

To investigate electroencephalogram (EEG) features' relation with mortality or functional outcome after disorder of consciousness, stratifying patients between continuous EEG and routine EEG. Retrospective analysis of data from a randomized controlled trial. Multiple adult ICUs. Data from 364 adults with acute disorder of consciousness, randomized to continuous EEG (30-48 hr; n = 182) or repeated 20-minute routine electroencephalogram (n = 182). None. Correlations between electrographic features and mortality and modified Rankin scale at 6 months (good 0-2) were assessed. Background continuity, higher frequency, and reactivity correlated with survival and good modified Rankin scale. Rhythmic and periodic patterns carried dual prognostic information: lateralized periodic discharges were associated with mortality and bad modified Rankin scale. Generalized rhythmic delta activity correlated with survival, good modified Rankin scale, and lower occurrence of status epilepticus. Presence of sleep-spindles and continuous EEG background was associated with good outcome in the continuous EEG subgroup. In the routine EEG group, a model combining background frequency, continuity, reactivity, sleep-spindles, and lateralized periodic discharges was associated with mortality at 70.91% (95% CI, 59.62-80.10%) positive predictive value and 63.93% (95% CI, 58.67-68.89%) negative predictive value. In the continuous EEG group, a model combining background continuity, reactivity, generalized rhythmic delta activity, and lateralized periodic discharges was associated with mortality at 84.62% (95%CI, 75.02-90.97) positive predictive value and 74.77% (95% CI, 68.50-80.16) negative predictive value. Standardized EEG interpretation provides reliable prognostic information. Continuous EEG provides more information than routine EEG.