Femoral tunnel placement in anterior cruciate ligament reconstruction: rationale of the two incision technique.

Fiche du document

Date

2007

Discipline
Type de document
Périmètre
Langue
Identifiants
Relations

Ce document est lié à :
info:eu-repo/semantics/altIdentifier/doi/10.1186/1749-799X-2-10

Ce document est lié à :
info:eu-repo/semantics/altIdentifier/pmid/17511888

Ce document est lié à :
info:eu-repo/semantics/altIdentifier/eissn/1749-799X

Ce document est lié à :
info:eu-repo/semantics/altIdentifier/urn/urn:nbn:ch:serval-BIB_3D14434D59970

Licences

info:eu-repo/semantics/openAccess , Copying allowed only for non-profit organizations , https://serval.unil.ch/disclaimer



Citer ce document

R. Garofalo et al., « Femoral tunnel placement in anterior cruciate ligament reconstruction: rationale of the two incision technique. », Serveur académique Lausannois, ID : 10.1186/1749-799X-2-10


Métriques


Partage / Export

Résumé 0

Endoscopic anterior cruciate ligament (ACL) reconstruction can be performed through one-incision or two-incision technique. The current one-incision endoscopic ACL single bundle reconstruction techniques attempt to perform an isometric repair placing the graft along the roof of the intercondylar notch, anterior and superior to the native ACL insertion. However the ACL isometry is a theoretical condition, and has not stood up to detailed testing and investigation. Moreover this type of reconstruction results in a vertically oriented non-anatomic graft, which is able to control anterior tibial translation but not the rotational component of the instability. Femoral tunnel obliquity has a great effect on rotational stability. To improve the obliquity of graft, an anatomical ACL reconstruction should be attempt. Anatomical insertion of ACL on the femur lies very low in the notch, spreading between 11 and 9-8 o'clock position and the center lies lower than at 11 o'clock position. Femoral aiming devices through the tibial tunnel aim at an isometric placement, and they do not aim at an anatomic position of the graft. Also, a placement of tunnel in a position of 11 o'clock is unable to restore rotational stability. The two-incision technique, with the possibility to position femoral tunnel independently by tibial tunnel, allows us to place femoral tunnel entrance in a position of 10 'clock that can most accurately reproduce the anatomic behaviour of the ACL and can potentially improve the response of the graft to rotatory loads. This positioning results in a more oblique graft placement, avoiding problem related to PCL impingement during knee flexion. Further studies are required to understand if this kind of reconstruction can ameliorate proprioception as well as clinical outcome at a long-term follow-up.

document thumbnail

Par les mêmes auteurs

Sur les mêmes sujets

Sur les mêmes disciplines

Exporter en