Performance of a diagnostic algorithm for fibrotic hypersensitivity pneumonitis. A case-control study.

Fiche du document

Date

23 avril 2021

Type de document
Périmètre
Langue
Identifiants
Relations

Ce document est lié à :
info:eu-repo/semantics/altIdentifier/doi/10.1186/s12931-021-01727-7

Ce document est lié à :
info:eu-repo/semantics/altIdentifier/pmid/33892724

Ce document est lié à :
info:eu-repo/semantics/altIdentifier/eissn/1465-993X

Ce document est lié à :
info:eu-repo/semantics/altIdentifier/urn/urn:nbn:ch:serval-BIB_F8812E17079F3

Licences

info:eu-repo/semantics/openAccess , CC BY 4.0 , https://creativecommons.org/licenses/by/4.0/




Citer ce document

S.A. Guler et al., « Performance of a diagnostic algorithm for fibrotic hypersensitivity pneumonitis. A case-control study. », Serveur académique Lausannois, ID : 10.1186/s12931-021-01727-7


Métriques


Partage / Export

Résumé 0

The differential diagnosis fibrotic hypersensitivity pneumonitis (HP) versus idiopathic pulmonary fibrosis (IPF) is important but challenging. Recent diagnostic guidelines for HP emphasize including multidisciplinary discussion (MDD) in the diagnostic process, however MDD is not comprehensively available. We aimed to establish the diagnostic accuracy and prognostic validity of a previously proposed HP diagnostic algorithm that foregoes MDD. We tested the algorithm in patients with an MDD diagnosis of fibrotic HP or IPF (case control study) and determined diagnostic test performances for diagnostic confidences of ≥ 90% and ≥ 70%. Prognostic validity was established using Cox proportional hazards models. Thirty-one patients with fibrotic HP and 50 IPF patients were included. The algorithm-derived ≥ 90% confidence level for HP had high specificity (0.94, 95% confidence interval [CI] 0.83-0.99), but low sensitivity (0.35 [95%CI 0.19-0.55], J-index 0.29). Test performance was improved for the ≥ 70% confidence level (J-index 0.64) with a specificity of 0.90 (95%CI 0.78-0.97), and a sensitivity of 0.74 (95%CI 0.55-0.88). MDD fibrotic HP diagnosis was strongly associated with lower risk of death (adjusted hazard ratio [HR] 0.10 [0.01-0.92], p = 0.04), whereas the algorithm-derived ≥ 70% and ≥ 90% confidence diagnoses were not significantly associated with survival (adjusted HR 0.37 [0.07-1.80], p = 0.22, and adjusted HR 0.41 [0.05-3.25], p = 0.39, respectively). The algorithm-derived ≥ 70% diagnostic confidence had satisfactory test performance for MDD-HP diagnosis, with insufficient sensitivity for ≥ 90% confidence. The lowest risk of death in the MDD-derived HP diagnosis validates the reference standard and suggests that a diagnostic algorithm not including MDD, might not replace the latter.

document thumbnail

Par les mêmes auteurs

Sur les mêmes sujets

Exporter en