The Influence of Methods for Cardiac Output Determination on the Diagnosis of Precapillary Pulmonary Hypertension: A Mathematical Model.

Fiche du document

Date

4 janvier 2023

Type de document
Périmètre
Langue
Identifiants
Relations

Ce document est lié à :
info:eu-repo/semantics/altIdentifier/doi/10.3390/jcm12020410

Ce document est lié à :
info:eu-repo/semantics/altIdentifier/pmid/36675338

Ce document est lié à :
info:eu-repo/semantics/altIdentifier/pissn/2077-0383

Ce document est lié à :
info:eu-repo/semantics/altIdentifier/urn/urn:nbn:ch:serval-BIB_29C6F37820A83

Licences

info:eu-repo/semantics/openAccess , CC BY 4.0 , https://creativecommons.org/licenses/by/4.0/



Sujets proches En

Pattern Model

Citer ce document

L. Genecand et al., « The Influence of Methods for Cardiac Output Determination on the Diagnosis of Precapillary Pulmonary Hypertension: A Mathematical Model. », Serveur académique Lausannois, ID : 10.3390/jcm12020410


Métriques


Partage / Export

Résumé 0

Background: precapillary pulmonary hypertension (PH, PcPH) is now defined as a mean pulmonary artery pressure (mPAP) > 20 mmHg, a pulmonary artery wedge pressure (PAWP) ≤ 15 mmHg and a pulmonary vascular resistance (PVR) > 2 WU. For PVR calculation, the measurement of cardiac output (CO) is necessary. It is generally measured using thermodilution. However, recent data showed that the agreement with direct Fick method, historically the gold standard, is less than previously reported. We aimed to create a mathematical model that calculated the probability of being classified differently (PcPH or unclassified PH) if CO measured by direct Fick was used instead of thermodilution for any individual patients with a mPAP > 20 mmHg and a PAWP ≤ 15 mmHg. Methods: The model is based on Bland and Altman analysis with a normally distributed difference of cardiac output, fixed 1.96 standard deviation of bias, bias and physiological cardiac output limits. Results: Following a literature review of the studies comparing CO measured with direct Fick and thermodilution, we fixed the 1.96 standard deviation of bias at 2 L/min, bias at 0 L/min and physiological resting CO limits between 1.3 L/min and 10.2 L/min. Conclusions: This model can help the clinician to evaluate the potential benefit of measuring CO using direct Fick during the diagnostic work-up and its utility in confirming or ruling out a diagnosis of PcPH in any given patient with a mPAP > 20 mmHg and a PAWP ≤ 15 mmHg.

document thumbnail

Par les mêmes auteurs

Sur les mêmes sujets

Sur les mêmes disciplines

Exporter en