APPLICATION OF CLEAN ALGORITHM IN INCOMPLETE MICROTREMORS RECORDINGS

Fiche du document

Date

1 janvier 2004

Discipline
Type de document
Périmètre
Langue
Identifiant
Source

eJournals

Relations

Ce document est lié à :
https://ejournals.epublishing.ekt.gr/index.php/geo [...]

Organisation

EKT ePublishing

Licences

Copyright (c) 2018 G. Hloupis, M. Moisidi, F. Vallianatos, J. P. Makris, J. Stonham, D. Triantis , https://creativecommons.org/licenses/by-nc/4.0


Sujets proches En

Microtremors Seismic noise

Citer ce document

G. Hloupis et al., « APPLICATION OF CLEAN ALGORITHM IN INCOMPLETE MICROTREMORS RECORDINGS », eJournals, ID : 10670/1.l6zsrl


Métriques


Partage / Export

Résumé 0

The reconstruction of gapped microtremors recordings with the aid of CLEAN algorithm, which originally developed for spectral analysis of unevenly spaced time series, is studied. As proved in previous relative studies the algorithm has the ability to "clean" the spectrum of a discrete signal from artifacts and additionally (through an Inverse DFT) to reconstruct the signal in time domain. We studied the algorithm's effectiveness of reconstruction in microtremors recordings. We saw that for continuous gap with length up to 10% of the total length of microtremor recording, the algorithm was able to reconstruct efficiently.

document thumbnail

Par les mêmes auteurs

Sur les mêmes sujets

Sur les mêmes disciplines

Exporter en